TM 5-1940-277-20
TM 1940-20/2
REMOVAL: Switch
NOTE
All switches and alarm reset buttons are removed and
installed the same way. Only one switch is shown.
Tag all electrical leads for installation.
1.
Using cross tip screwdriver remove six screws (1) and pull instrument panel (2) out from
console (4).
2.
If necessary, cut and remove tie-strap (30) from electrical leads (28).
3.
Disconnect electrical leads (28) from switch (29).
4.
Remove rubber boot (31) and/or nut (32) from instrument panel (2).
5.
Remove switch (29) from instrument panel (2).
INSTALL: Switch
1.
Install switch (29) on instrument panel (2).
2.
Install rubber boot (31) or nut (32) securing switch (29) on instrument panel (2).
NOTE
Install electrical leads as noted at removal.
3.
Connect electrical leads (28) on switch (29).
4.
If removed, install new tie-strap (30) on electrical leads (28).
5.
Using cross tip screwdriver install six screws (1) securing instrument panel (2) on console (4).
REMOVE: Indicator
NOTE
There are four orange, two green, and two red indicators. All
indicators are removed and installed the same way. Only one
indicator is shown.
Tag all electrical leads for installation.
1.
Using long nose pliers cut indicator electrical leads (34) from harness (36) at splice terminals (35).
2.
Remove indicator (33) by pushing it through front of instrument panel (2).
INSTALL: Indicator
1.
Apply light coat of RTV sealant to indicator (33).
2.
Feed electrical leads (34) through hole in instrument panel (2).
3.
Push indicator (33) through hole in instrument panel (2) until seated.
4.
Wipe up any excess RTV sealant on face of instrument panel (2).
NOTE
Install electrical leads as noted at removal.
5.
Connect two indicator electrical leads (34) to harness (36) with splice terminals (35).
6.
Using long nose pliers crimp splice terminals (35).
3-102.5
Change 2