TM 5-1940-277-20
TM 1940-20/2
INSTALL:
1.
Route cable harnesses and power leads through console opening, aline switch panel unit 2 (1) with mounting holes,
and secure with 12 screws (2) using crosstip screwdriver.
2.
Insert switch panel unit 2 cable harnesses (3), (4) and (5) through cable glands (6) on junction box unit 2 (7).
Observing lead numbers, connect cable harnesses leads (3), (4) and (5) to respsctive tagged quick disconnect re-
3.
ceptacles (8) in junction box unit 2 (7).
Insert power leads + and - (9) through cable glands (10) on junction box unit 1 (11) and connect power leads (9)
4.
to terminals (12).
5.
Use open end wrench and adjustable wrench to tighten cable gland hex nuts (6) and (10) on junction boxes as indicated.
NOTE
Make sure junction box cover gaskets and o-rings are not damaged. Replace damaged
o-ring or gasket.
6.
Install junction box cover (13) and (14) and secure with four screws (15) and (16) on each junction box using crosstip
screwdriver.
7.
Refer to paragraph 3-154 and dose access panel under control console.
3-113
|
||