Figure 4-23. Hand pump, cross-section view.
(2) Remove plunger gland retaining ring (28) from pump housing (1). Gland (29) will come out on plunger (22) when
plunger is pulled from housing (1). Remove gland (29) from plunger.
(3) Remove discharge check valve seat (12) from end of plunger (22). Discharge check valve (16)and spring (17) will
drop out of plunger.