TM 55-1905-219-14-1
Heat Interchange
Manufacturer
Dunham Bush (Heat X Inc)
Model
7-1/2 SX
Overall Length
22-3/4 inch (57.8 cm)
Shell Diameter
3-1/2 inch OD (8.9 cm)
Connections
7/8 inch (2.2 cm) OD liquid,
1-5/8 inch (4.1 cm) suction
Cooling Coil
Manufacturer
McIntyre
Model
56DF
Capacity
7.5 tons
Air Quantity
1260 cfm
Face Velocity
252 fpm (76.9 mpm)
Entering Air Temp
85.2F DB (29.6C)
74.0F WB (23.3C)
Leaving Air Temp
*WB
*DB
*Leaving Air Temperature to be established by the shipyard.
HEATERS
Manufacturer
Wiegand El Div. of Emerson Electric
Duct Type
1.3 kw
Model
DHMS-2F-008-W04H
Voltage
120
Phase
1
Element
One
Location
Wardroom Stateroom
Duct Type
2.2 kw
Model
DHMS-2F-012-W06H
Voltage
480
Phase
1
Elements
Two
Location
Pilot House
Duct Type
2.5 kw
Model
DHMS-2F-018-W06H
Vac
480
Phase
1
Element
One
Location
Radio Room
Duct Type
3.3 kw
Model
DHMS-2F-012-W06H
Vac
480
Phase
1
Elements
Two
Location
Crew Berthing
Duct Type
3.8 kw
Model
DHMS-2F-012-W08H
Vac
480
Phase
3
Elements
Three
Location
Galley/Mess
1-56