124
MONTHLY
Equipment and Repair
SEWAGE AIR PUMP.
(2-40-O-A)
OIL SEPARATOR LEVEL. Check oil level in
oil gage (6). To add oil, remove pipe plug
(7). Use oil (MIL-L-9000H (SH))
(nondetergent).
PUMP OIL LEVELS. Check oil levels in sight
valves (8). If oil is not visible, check oil level
on o gage (6). Add oil (MIL-L-9000H (SH))
(nondetergent). Purge system by loosening
fittings (9).
125
MONTHLY
Air Conditioning Room
Corroded or
worn.
DRAINING. Drain water by opening valves
(6).
ZINC PROTECTORS. Remove protectors
(7), check for corrosion. Clean with wire
brush. Replace when badly worn.