TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
127
MONTHLY
At SER Sites FR 12,
HALON SYSTEM - General. Check that all
Functional test
FR 48, FR 56
fails.
components are securely mounted and
installed at proper sites. Also check that all
wiring and electrical connections are secure.
Inspect for any physical damage of the parts.
Inspect all plumbing connections in the
system.
Perform the functional test of the Detection
System. (Refer to paragraph 2-123).
128
MONTHLY
General
DOORS, HATCHES, SCUTTLES, AND
They fail to seal.
MANHOLES.
NOTE
Use
grease
(MIL-G-18458B
(SH)).
Doors - Lubricate hinges (2), link (3), and
dogs (4).
Hatches - Lubricate hinges (5), link (6), and
dogs (7).
Change 4 2-171


 


Privacy Statement - Copyright Information. - Contact Us