Remove elbow (1 0) from reserve tank (3).
Continued
Remove nuts (11), washers (12). Remove
cover plate (13) and gasket (14). Clean the
screen element (15). Replace elbow (10).
Remove orifice head (16), gasket (17), and
filter (18). Clean the filter and the hole in the
orifice filter body (19). Replace filter (18),
gasket (17) and orifice head (16).
Replace gasket (14), cover plate (13),
washers (12) and nuts (11).
Replace pipe plugs (2 and 5). Open vent
valve (19). Open bleed valve (20). Remove
fill cap (21). Add approximately 7 gallons
(26.5 l) of oil (MIL-L-9000H (SH)). Stop
when oil flows from vent (19). Close vent
(19). Continue filling until oil level reaches
filler opening. Close bleed valve (20).
Replace and tighten fill cap (21).
Remove cap (22). Fill with approximately 3
quarts (2.84 liters) of oil (MIL-L-9000H (SH)).
NOTE
Fill to one inch (2.54 cm) below
full mark on dipstick.
Replace cap (22), and start engine and
operate at 1/2 throttle. Check for leaks.
Check pressure gage (23). Normal operation
pressure is 45 to 652 PSI (31.64 to 45.70
2
kg/cm ).
Check temperature gage (24). Normal
operating temperature is less than 200F
(93.3C).
The oil pressure and temperature are
measured with the converter properly filled
and vented.