Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
166
SEMI-
Equipment General
AIR HORN COMPRESSOR
Fails to hold
ANNUAL
pressure.
OIL CHANGE. Oil in the crankcase should
be changed after every 5000 hours of
operation. The crankcase should be
thoroughly cleaned at time of every oil
change. A threaded pipe plug (8) is provided
in the crankcase oil sump for draining.
Remove oil drain plug and drain oil into a
suitable container. Replace oil drain plug
and add 1/4 pint of oil (MIL-L-9000H (SH)).
Change 4 2-209
|
||