5-23. HYDROSTARTER-ENGINE DRIVEN PUMP-MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
OVERHAUL-DISASSEMBLY (Cont)
OVERHAUL-REPAIR
2. Replace all defective parts with serviceable-like items.
OVERHAUL-REASSEMBLYI
3.
a. Inlet
1. Install new inlet
Use repair kit.
valve
spring valve (49).
(48)
2. Install inlet valve
(48).
3. Install back-up ring
Use repair kit.
(47).
4. Install packing (46).
Use repair kit.
5. Install adapter fit-
ting (45) into valve
housing (23).