5-24. HYDROSTARTER SOLENOID-MAINTENANCE INSTRUCTIONS.
This task covers:
a. Inspection
c. Disassembly
e. Reassembly
b. Removal
d. Cleaning
f. Installation
INITIAL SETUP:
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition
Condition Description
NONE
NONE
Material/Parts
Special Environmental Conditions
Gasket kit P/N 919428
NONE
Personnel Required
General Safety Instructions
1
NONE
LOCATION
ITEM
ACTION
REMARKS
WARNING
To avoid possible injury, turn off all electrical power and relieve hydraulic pressure.
INSPECTION
1. Hydro-
a. Tubing
Inspect for breaks, bends,
starter
cracks, and leaking.
b. Wiring
Inspect for breaks, cracks
and worn insulation.
c.
Valve
Inspect for cracks and
leaking and that hardware
is tight.
5-419


 