Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-10
5-49. WINCH ASSEMBLY-MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
WARNING
(Continued)
Verify that all power has been shut off, and that the power source has been
properly tagged before proceeding.
To prevent the possibility of fire when using cutting or welding equipment, place
a crewman above and below the deck with fire extinguishers.
In order to avoid possible serious injury, place the circuit breaker in the OFF
position and tag. Place the disconnect switch in the OFF position and tag.
DEATH
or severe injury may result if personnel move around in the winch compartment
with the winch running.
Do not enter the winch compartment alone.
Disconnect power to the winch whenever working on the ramp gate, the wire
rope, or in the vicinity of the winch in the winch room.
Improper selection and installation of a brake and/or lack of maintenance, may
cause brake failure which could result in injury to personnel.
REMOVAL
1. Bow
a. Electric
Tag and disconnect.
Refer to wiring
Ramp
brake
diagram on page
Winch
wiring
5-661.
b. Motor
Tag and disconnect.
wiring
c.
Cable
Disconnect and remove.
Refer to para-
graph 5-48.
5-659
|
||