5-65.2 DISCONNECT CLUTCH-ANCHOR WINCH-MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
CAUTION
Use correct grease and do not overlubricate.
g. Release
Inspect the lever for
lever
the condition of the
(13)
toggle link hole; if
and
elongated or worn, re-
associ-
place the lever. Also
ated
check the milled slot in
parts
the underside of the
lever; if excessively
worn by fulcrum studs,
replace lever. A remov-
able fulcrum guide button
can be replaced if worn.
Needle bearings must
rotate freely; otherwise
replace. When installing
new needle bearings, use
suitable tool and press
in flush with lever. Make
certain they are installed
in the lever so that the
part number stamped on the
end of the needle bearing
cage faces outward as
pressing on the other end
of the bearing cage to
install will damage the
bearing. Pack needle
bearing with a small
amount of high melting
point grease.
h. ever
Notice the condition
adjust-
of the lever adjusting
ing
screws. If they are
screws
worn where contacted
(15)
by the release bearing,
install new screws in
the levers.