Custom Search
 
  
 
TM 55-1905-219-14-11
5-89.1. STARTER (NEMA, SIZE D, 3 POLE) - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
c.
Armature
1. Tilt the top away
(4)
from coil (5).
2. Slide armature up
and out.
d. Spring
Remove.
plate
(6)
e. Coil (5)
1. Pull straight out.
2. Replace.
Coil terminal
blades must
engage coil
terminal clips.
f.
Spring
Install and seal.
plate
(6)
5-1147


 