TM 55-1905-219-14-11
5-121.1. CONTACTOR (NEMA SIZE 3, 2, AND 3 POLE AC)-MAINTENANCE
INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
6.
Place and hold
Use new spring,
retainer (35), in
retainer, and
the position shown.
movable contact.
7.
Compress spring (36)
with thumb and index
finger, and insert
and seat in the
cavity above the
retainer (35).
8.
Raise the retainer
Contact tips
(35) against the
must face away
spring (36), insert
from the
and position the
retainer.
movable contact
(37).
d.
Contact
Install.
bar (34),
screws
(31),
lock-
washers
(32)
and
flat-
washers
(33)
5-1352
|
|