Custom Search
 
  
 
TM 55-1905-219-14-11
5-121.2. CONTACTOR (NEMA SIZE 3, 3 POLE REVERSING)-MAINTENANCE
INSTRUCTIONS.
This task covers:
Repair
INITIAL SETUP
Test Equipment
References
Paragraph
NONE
4-8.1
Contactor
4-8.4
Fire Pump Controller
Equipment
Special Tools
Condition
Condition Description
NONE
NONE
Material/Parts
Special Environmental Conditions
Renewal set contacts
NONE
6-25-2
Personnel Required
General Safety Instructions
1
Observe WARNING in this procedure.
LOCATION
ITEM
ACTION
REMARKS
To prevent accidental shock and possible injury, tag and place
disconnect switch in the OFF position, and pull fuses as an added
precaution.
REPAIR
NOTE
This starter is similar to the contactor in paragraph 4-8.1. The power
unit in this starter is identical to the power unit in contactor in paragraph
4-8.1.
5-1355


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business