Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-2
2-37. GENERATOR ENGINE - LOCAL START.
Before starting engines, generator circuit breakers on control panel must be open.
a.
Perform all before and daily operations on the Preventive Maintenance Checks and Services Chart.
NOTE
Position all shut off valves open (counter-clockwise).
b.
Operate hand pump (1) on hydrostarter in forward engine room to charge accumulator (2 and 3).
c.
Pressure gage (4 and 5) should read:
AMBIENT TEMPERATURE
GAGE READING
Above 40 (4.4 )
F
C
1500 psi (1054.5 kg sq cm)
40 to 0 (4.4 to -17.8 )
F
F
C
C
2500 psi (1757.5 kg sq cm)
Below 0 (-17.8 )
F
C
3300 psi (2319.9 kg sq cm)
2-268
|
||