Custom Search
 
  
 
TM 55-1905-219-14-2
2-74. TANK LEVEL INDICATING SYSTEM (Cont).
(e)
Lamp (11) above the meters will light if the fluid level In the tank is too high.
(f)
Lamp (12) above the meter will light if the fluid level in the tank is too low.
(g)
An audible alarm (13) will sound if the alarm silence switch (14) is placed in the ON position and either lamp
(11 or 12) is lit.
2-75. FIRE, BILGE, AND BALLAST SYSTEM.
a.
The fire, bilge, and ballast system is used to supply sea water for fighting fires, filling or emptying the ballast
tanks, to wet down the weather decks and super-structure, and for bilge draining. The systems are
interconnected with the main components a fire pump and a bilge pump.
Change 2
2-390


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business