2-78. FIRE PUMP - SHUTDOWN (Cont).
d.
Aft Engine Room.
(1)  Check valve (6) lever in full clockwise.
(2)
Clean the simplex strainer as follows:
(a)
Loosen yoke screw (7).
(b)
Remove bolts (8), yoke (9), cover (10), and gasket (11).
Use eye protection when using compressed air.
(c)
Remove strainer (12), clean with clean water and dry with compressed air.
(d)
The strainer (12) can be drained by removing pipe plugs (13).
(e)
Replace pipe plugs (13), strainer (12), gasket (11), cover (10), yoke (9) and bolts (8).
(f)
Tighten yoke screw (7).
2-398


 