2-80.1 WASHDOWN COUNTER-MEASURE SPRINKLER SYSTEM.
a.
A salt water washdown counter-measure sprinkling system is provided to thoroughly wet down the weather
decks and super-structure. Spray nozzles are located as shown
b. The fire stations located on the vehicle deck have portable fog applicators for washdown.
The fire pump must be supplying water to the firemains.
Refer to paragraph 2-77 for fire pump operating procedures.
c.
Operating the washdown countermeasure sprinkling system.
(1)
Reefer room (2-28-0-A).
Lock valve (1) in the open position.
(2)
Pilot house.
(a)
Drain valve (2) must be in the clockwise (closed) position.
(b)
Rotate control valve (3) clockwise to open.
(c)Water will now be spraying on the weather decks and superstructure.