2-83. DRAINING BILGE WITH BILGE PUMP (Cont).
b.
Refer to paragraph 2-90 for the method of draining the bilge using both the bilge pump and the fire pump.
c.
To operate the bilge pump refer to figure FO-40 and proceed as follows:
(1) Aft Engine Room.
Place flow control valve (1) in the closed position.
(2) Forward Engine Room.
(a)
Place flow control valve (2) in the open position.
(b)
Place flow control valve (3) in the open position.
(c)
Rotate the overboard discharge check valve (4) clockwise.
(d)
Rotate the remote control valve (5) counter-clockwise.
(e)
The port propulsion engine must be running. The clutch on the marine gear does not need to be in either
forward or reverse.
(f)
Pull out knob (6) on local throttle control (7).
(g) Rotate knob (6) one-quarter turn counter-clockwise.