2-102. SEWAGE SYSTEM - NORMAL OPERATION (Cont).
(d)
On the alarm switchboard:
1
Bell will ring.
2
Alarm target will be red.
(2)
During normal operation of the sewage system, the need to shut down the system is minimal. Usually, one of
the macerator pumps is shut down: not both. To shut down a macerator pump, place the disconnect switch in
the OFF position. Place the lever on the input ball valve in the OFF position.
2-103. OVERBOARD DISCHARGE - HOLDING TANK.
a.
When the holding tank is full, the contents should be discharged to a dock side tank. Refer to Figure FO-55 and
proceed as follows:
Federal law prohibits dumping of raw sewage in restricted waters.
(1)
Engine Access Room.
Place circuit breakers #8 and 9 on power distribution panel (P-400) in the ON position.