TM 55-1905-219-14-2
2-111. ALARM SYSTEM TURN-ON (Cont).
(e) The alarm system is operational.
NOTE
If the alarm system is being turned on for the first time, or after being serviced-perform
the tests in paragraph 2-113.
2-112. SYSTEM ALARMS.
a.
The alarm system switchboard gives audible and visual alarms as follows:
SUPERVISORY-Trouble in the circuit. A buzzer will sound. A yellow target is visible. There
is a problem in the sensing device, or the wiring to the alarm switchboard.
ALARM-Dangerous situation. A bell will ring. A red target is visible. There is a problem in
the following: propulsion engine, generator engine, sewage tank, magazine, or gyro
compass.
b.
The alarms are as follows:
(1)
SUPERVISORY ALARMS-The target is as follows:
Gray-normal
Yellow-OFF BUZZER will sound
2-481


 