2-198. STARTING - PORTABLE FIRE PUMP.
a. To start the portable fire pump, proceed as follows:
NOTE
Perform all preliminary adjustments (para 2-197).
(1) On fuel tank, press push button (1) several times, until resistance is felt.
Do not continue to press button after resistance is
felt. Damage to a diaphragm may result.
(2) Place water outlet valve (2) in the closed position.
(3) Check that wing nut (3) on hand priming filler bowl (4) is tight.