2-198. STARTING - PORTABLE FIRE PUMP (Cont).
c.
To adjust water pressure, proceed as follows:
Using a screwdriver, adjust screw. Maximum pressure is limited by number and size of nozzles used.
d. To check the level of fuel in the tank:
Observe fuel gage.
An explosion or fire can result from improper
handling of gasoline. Stop pump - remove fuel
tank - refill in a well ventilated area.
2-199. APPLICATIONS - PORTABLE FIRE PUMP.
a. The fire pump can be used for the following:
emptying peak ballast tank
fighting fires
salvage
b. The fire pump can lift water:
16 to 20 feet (4.9 to 6.1 meter) using foot valve.
greater than 20 feet (6.1 meters) using eductor.