Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-11. Hydrostarter - Low or No Accumulator Pressure - Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Engine driven pump fails to raise pressure (Cont).
b. If the accumulator can be
charged with the hand pump
but not with the engine-
driven pump, then a check
valve in the engine pump
is defective. Replace the
faulty check valve assembly.
Refer to paragraph 3-48.
Step 5.
Check for defective drive.
Replace the pump drive arm.
Refer to paragraph 3-48.
Table 3-12. Hydrostarter - Cranking Speed Too Low -
Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Cranking speed to low.
Step 1.
Check that hydrostarter system fluid is not too heavy.
Check the fluid in the system. Use Hydraulic Fluid MIL-L-17672 type 2135
TH.
Step 2.
Check that engine oil is not too heavy.
Replace the oil with the proper viscosity grade.
3-66


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business