TM 55-1905-219-14-3
Table 3-15. Hydrostarter - Hand Pump Fails to Discharge Fluid - Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Hand pump fails to discharge fluid (Cont)
Step 5.
Check for air in system.
To purge the hand pump of air:
a. Relieve any system pressure,
then disconnect the outlet
hose from the hand pump.
b. Close the manual relief valve
and operate the pump until
fluid is discharged when
stroking in both directions.
c. Reconnect the outlet hose.
Step 6.
Check for dirt in pump.
See step 2.
Step 7.
Check for damaged piston seal rings.
Replace the seal rings. Refer
to paragraph 3-49.
3-72