Tweet |
![]()
Custom Search
|
|
![]() |
||
![]() TM 55-1905-219-14-3
Table 3-24. Generator Engine - Abnormal Engine Operation
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Lack of power.
Step 1. Check for improper engine adjustments, and gear train timing.
Perform adjustments in paragraphs 3-66, 3-79, 3-87 and 3-90, if performance is
not satisfactory.
Check the engine gear train timing. An improperly timed gear train will result in a
loss of power due to the valves and injectors being actuated at the wrong time in
the engine's operating cycle. Refer to paragraph 3-90.
Step 2. Check for insufficient fuel.
Perform a Fuel Flow Test and, if less than 0.8 gallons per minute with engine at
1200 RPM, consult the No Fuel or Insufficient Fuel Table 3-25.
3-89
|
||
![]() |