Table 3-43. Switchboard Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARING
HIGH VOLTAGE
is used in operation of this equipment.
DEATH ON CONTACT
may result if safety precautions are not observed.
Remember 450 volts in a salt water atmosphere can
be deadly. There are three potential sources of
power: Generator 1, Generator 2, and Shore power.
Place warning tags (red) on generator instrument
panels on the forward and aft engine room, to
prevent accidental starting of generators.
NOTE
Prior to starting troubleshooting the switch board
and generators, perform the operating procedures
in paragraph 2-35. When a problem occurs, consult
this table for a possible solution after observing
the front panel meters.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Starter cranks generator but stops when start switch is released.
Step 1.
Check for defective start solenoid.
Replace. Refer to paragraph 3-52.
Step 2.
Check for defective start switch.
Refer to Direct Support Maintenance.