Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-51. Anchor Winch Torque Converter
Troubleshooting (Cont).
NOTE
Refer to paragraph 3-136 for maintenance unless otherwise noted.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of fluid from converter.
b. Low oil pressure may also be caused by converter fluid entering lube oil
chamber or by fluid entering turbine bearing chamber. To check fluid
leakage, disconnect seal drain lines, then close line so fluid from
reserve tank will not escape.  With converter operating, observe
leakage at seal drain outlet and if excessive (a steady stream), repair.
Refer to Direct Support Maintenance.
3-157


 