Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-57. Anchor Winch Hydraulic Tank Troubleshooting.
NOTE
Refer to paragraph 3-137 for all maintenance procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Loss of fluid from hydraulic tank assembly.
Step 1.
Inspect for leaky pipe connections.
Check all lines and connections. Be sure no rubbing or
excessive vibration is present. Have
system under pressure when looking for leaks.
Step 2.
Check for leaky tank.
Check all bolts clamping gasketed cover while system \
is under pressure.
Step 3.
Check for excessive leakage in gaskets.
This may be indicated by low pressure on gages.
Low pressure may indicate the filter is clogged.
Replace filter.
2.
Poor performance.
Step 1.
Check for dirty air filter.
Remove and clean.
Step 2.
Check for dirty strainer.
Remove and clean.
Step 3.
Check for low pressure.
a.
Check the gauges for damage.
Replace.
b.
Gauge valves.
Clean and adjust.
3-171


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business