Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-58. Anchor Winch Hydraulic Pump - Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Lack of pressure.
Step 1.
Check to see if pump speed is not same as engine.
Check key in shaft.
Step 2.
Check for dirt inside pump.
a. Check filter on hydraulic tank.
b. Drain oil, disassemble pump and clean.
Step 3.
Inspect for defective drive gears.
Replace.
Table 3-59. Anchor Winch Engine - Exhaust Smoke Analysis - Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Black or grey smoke.
Step 1.
High exhaust back pressure is caused by faulty
exhaust piping or muffler obstruction. Remove
air box covers.
Clean ports in cylinder liner. Refer to Direct Support Maintenance.