Custom Search
 
  
 
TM 11-1905-219-14-3
Table 3-70. Anchor Winch Engine - Hydrostarter - Loss of Fluid
From Reservoir - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of fluid from reservoir.
Step 1.
Check for external leaks.
With pressure in the system, check all hoses and fittings for leaks. Tighten
the fittings. Refer to Direct Support Maintenance.
Step 2.
Check for worn starter shaft seal.
Remove the starter after releasing the system pressure. If evidence of
system fluid is found, refer to Direct Support Maintenance.
Step 3.
Check for defective gasket under starter cover.
Operate the starter. During the cranking cycle, watch closely for fluid
leaking around cover or any of the retaining bolts. Refer to paragraph 3-176.
Step 4.
Check for worn shaft seal.
Refer to Direct Support Maintenance.
3-214


 