Custom Search
 
  
 
TM 11-1905-219-14-3
Table 3-71. Anchor Winch Engine - Hydrostarter - Loss of Fluid
Pressure When Engine is Not Running - Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of fluid pressure when engine is not running (Cont.).
Step 5.
Check for damaged middle seal ring in starter control valve. Make sure
there is no visible external leakage.
Disconnect the return hose from the starter. Use the hand pump to raise
the pressure if necessary. If fluid leaks from the return fitting when the
control valve is closed, the middle seal ring is damaged. Remove the
control valve and replace the seal ring. Refer to paragraph 3-176.
Step 6.
Check for external leakage in system.
Examine all hoses and fittings for leaks. Tighten. Refer to Direct Support
Maintenance.
Step 7.
Check for starter control valve out of time. Check for bent shifting fork.
Refer to Direct Support Maintenance.
Step 8.
Check for loss of accumulator precharge (nitrogen).