Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-81. Stern Gate Hydraulic System - Troubleshooting.
(Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Sluggish operation.
Step 1.
Check centralized hydraulic system.
Refer to table 3-79.
Step 2.
Check directional control valve.
Damaged control valve.
Refer to paragraph 3-194.
Step 3.
Check for misadjusted flow control valves.
Readjust.
Step 4.
Check hydraulic cylinders.
a. Remove accumulations of salt.
b. Replace
Refer to paragraph 3-196.
Table 3-82. Mast Hydraulic System - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Inoperative.
Step 1.
Check centralized hydraulic system.
Turn system on. Refer to paragraph 2-63.
Change 2 3-231


 