TM 55-1905-219-14-4
3-9.6. HYDROSTARTER DEACTIVATE SWITCH - MAINTENANCE INSTRUCTIONS
(Cont).
LOCATION
ITEM
ACTION
REMARKS
Testing (Cont)
3. Engine
Instrument
a. Slow the engine down
The alarm will
panel
towards the no-fuel
not sound in
position while watch-
pilothouse.
ing the oil pressure
gage.
b. Observe hydrostarter
disconnect switch.
When the switch actu-
ates, observe the oil
pressure gage.
c. Note the oil pressure
at which the engine
If the pressure
shuts down.
is not 10 psi
(7.03 gm cm2 )
adjust the
hydrostarter
disconnect
switch.
Adjustment
4. Hydro-
a. Adjust- a. Adjust.
Adjust so that
starter
ing screw
the points open
disconnect
(3)
at 10 psi (7.03
2
switch
gm cm ).
3-412