3-11.2. AIR INTAKE HOUSING - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
Removal (Cont)
4.
Striker
a. Screws
Remove.
plate
(19),
(forward
lock-
and/or
washers
aft)
(20), and
flat-
washers
(21)
b. Striker
Remove.
plate
(22)
c. Gasket
Remove.
Discard.
(23)
d. Blower
Remove.
Clean or dis-
screen
card.
(24)
WARNING
Use eye protection when using compressed air.
NOTE
Clean all of the parts thoroughly, including the blower screen, with fuel
oil and dry them with compressed air. Inspect the parts for wear or
damage.  The face of the shutdown valve must be perfectly flat to
assure a tight seal when it is in the shutdown position.