TM 55-1905-219-14-4
3-17. LUBRICATING OIL COOLER - MAINTENANCE INSTRUCTIONS (Cont).
This task covers:
a. Removal
b. Cleaning
c. Installation
INITIAL SETUP
Test Equipment
References
NONE
NONE
Special Tools
Equipment
NONE
Condition
Condition Description
Material/Parts
Remove oil filter
Cleaning solutions:
Remove oil lines
(1) Trichloroethylene
(2) Oakite or alkaline
Special Environmental Conditions
solution
(3) Oxalic acid
Do not dump used cleaning
(4) Muriatic acid
solutions into the ocean.
Gasket kit P/N 5196375
Anti freeze (MIL-A-46153
Personnel Required
General Safety Instructions
3
Perform all cleansing
operations in well-
ventilated rooms.
Avoid breathing fumes
of chemicals or contact
with skin or eyes.
3-557