3-18. FRESH WATER PUMP - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REPAIR
Use care to prevent damage to the ceramic impeller insert. Place the impeller
on the bench with the insert up.
f. Impeller
Remove
Discard.
(26)
Use tool J22150.
g. Seal (27)
Remove
Place seal pul-
ler over seal
and into two
slots in the
pump body. Re-
move by turning
in a clockwise
direction.
h. Seal (27)
Install
To reduce pos-
sible coolant
leakage, apply
a light coat
of non-harden-
ing Permatex to
a new water
seal. Tap the
seal into seal
cavity with
tool J8501.