Custom Search
 
  
 
TM 55-1905-219-14-4
3-40.2. CONNECTING ROD-MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
LONGITUDINAL INDICATIONS
TRANSVERSE INDICATIONS (ACROSS FLOW LINES).
GRINDING NOTES
FOLLOWING FORGED FLOW LINES
HAVING A MAXIMUM LENGTH OF 1/2, WHICH CAN
CARE SHOULD-TAKEN IN ARE GRINDING OUT IN-
DICATIONS
TO
ASSURE
PROPER
ARE USUALLY SEAMS AND ARE NOT
BE REMOVED BY GRINDING ND DEEPER THAN 1/64
CONSIDERED HARMFUL IF LESS THAN
ARE ACCEPTABLE AFTER THEIR COMPLETE REMOVAL.
OF GROUND AREA INTO UNGROUND SURFACE
1/32 DEEP. DEPTH CAN BE DETER-
AN EXCEPTION TO THIS IS A ROD HAVING AN
SO AS TO FORM A SMOOTH CONTOUR.
MINED BY GRINDING A SMALL AREA
INDICATION WHICH EXTENDS OVER THE EDGE OF
NEAR THE CENTER OF THE INDICA-
"H" SECTION AND IS PRESENT ON BOTH SIDES
TION.
OF THE FLANGE. IN THIS CASE, MAXIMUM ALLOW-
ABLE OEPTH IS .005 (SEE SECTION A-A).
POOR PRACTICE GOOD PRACTICE
3-845


 


Privacy Statement - Copyright Information. - Contact Us