Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-4
3-50. HYDROSTARTER PIPING (FORWARD ENGINE ROOM) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
5.
Pressure
a. Check gages for
Refer to Direct
gages (5)
cracks or broken
Support Mainte-
glass.
nance.
b. Check fittings
and connections
for tightness
and leaks.
6.
Hand pump
Check for leaks.
Refer to para-
(6)
graph 3-45 for
maintenance.
7.
a. Check for leaks.
valve (7)
b. Check fittings.
Make sure they
are tight.
8.
Filter and
a. Check for leaks.
gasket (8)
b. Check for cracks,
dents and wear.
9.
Valve, ball
a. Check for leaks.
3000 lbs.
(9)
b. Check for cracks,
dents and wear.
c. Check fittings for
tightness.
REPLACEMENT
NOTE
Release the pressure in the hydrostarter system by opening relief valve
on side of the pump approximately 1/2 turn.
3-952
|
||