TM 55-1905-219-14-4
3.52.1. HYDROSTARTER RESERVOIR - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION
9.
Reservoir
a. Install clamps (12),
bolts (11), nuts (10)
on reservoir (1) and
mount onto bulkhead.
b. Install fine mesh
If necessary.
screen (8) into
reservoir (1).
c. Connect shutoff valve
(4) at elbow (7).
d. Connect supply piping
(6) to elbow (7) at
shutoff valve (4).
f. Install dry-type
filter (3).
g. Fill reservoir with
Use hydraulic
hydraulic fluid.
fluid (MIL-L-
17672, Type
2135 TH).
h. Replace and tighten
filler cap (2).
i. Check all fittings
and valves for leaks.
3-966
|
|