Custom Search
 
  
 
TM 55-1905-219-14-4
3-56.
SHAFT SEALS - MAINTENANCE INSTRUCTIONS.
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
EDGES NOT MATED, COMPLETELY MIS-ALIGNED. WHEN THESE
EDGES INTERFACE WITH HOUSING WALL, THE MIS-ALIGNED
AREA, HOWEVER SLIGHT, FORMS A LEAK PATH.
ALIGNMENT OF
SEALING ELEMENT
IN LIKE MANNER, IF MIS-ALIGNMENT OCCURS WHEN THE
HOUSING HALVES ARE PUT TOGETHER, LEAKAGE ALSO OCCURS.
Be sure ALL surfaces
are in perfect align-
ment.  If not, com-
pletely separate and
repeat procedures.
4. Hold sealing element
(27) in shaft for 20
to 30 seconds to allow
the cement to partially
set up.
3-1021


 