3-62.1. GENERATOR (12VDC)-MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (CONT)
b. Through
Insert through field
Tighten.
bolts
frame.
(21) and
lockwash-
ers (22)
NOTE
Make sure the armature is free to rotate before the brushes are placed against the
commutator.
28. Brushes
a. Brushes
Lift arm and insert
1. If new brushes
(20)
brushes.
are too long,
and
the commutator
brush
ends should be
arms
sanded until
(19)
each is short-
ened enough
for the spring
tension arm to
be properly lo-
cated on top
of the brushes.
Do not file or
notch the top
of the brushes.
2. Be sure the
brush leads are
bent so that
they will fol-
low the brushes
as they wear
shorter.
3. Be sure they do
not rub against
any part of the armature.
b. Screws
Install wiring.
(17) and
lock-
washers (18)