3-65.3.2. WATER TEMPERATURE ALARM SWITCH - MAINTENANCE INSTRUCTIONS
(Cont).
LOCATION
ITEM
ACTION
REMARK
TESTING (Cont)
b. Inter-
1. Place lever in the on
lock
position.
cocks
(3)
2. Restart the engine
immediately without
load. Run the engine
until the engine cools
down.
REMOVAL
3. Alarm
a. Screw
Remove.
switch
(4)
b. Cover
Remove.
(5)
c. Wiring
Disconnect.
d. Screws
Remove.
(6) and
lock-
washers
(7)
e. Switch
Remove.
(8)