Custom Search
 
  
 
TM 55-1905-219-14-5
3-65.3.3.
FUEL OIL PRESSURE ALARM SWITCH - MAINTENANCE INSTRUCTIONS
(Cont).
LOCATION
ITEM
ACTION
REMARKSS
ADJUSTMENTS (Cont)
7. Water
a. Jumper
Remove.
temper-
wire
ature
alarm
b. Cover
Install.
Switch
(6)
and
screw
(5)
8. Fuel
a. Wire
Reconnect.
oil
pres-
b. Cover
Install.
sure
(4)
alarm
and
switch
screw
(3)
REMOVAL
9. Fuel oil
a. Screw
Remove.
Pressure
(3)
alarm
switch
b. Cover
Remove.
(4)
c. Wiring
Disconnect.
d. Screws
Remove.
(9)
and lock-
washers
(10)
e. Switch
Remove.
(11)
10. Fuel oil
a. Terminals
Remove wires.
pressure
(12)
switch
b. Switch
Unscrew.
(13)
3-1182


 