Custom Search
 
  
 
TM 55-1905-219-14-5
3-65.3.4.
LUBRICATING OIL ALARM SWITCH - MAINTENANCE
INSTRUCTIONS
This task covers:
a. Testing
c. Removal
b. Adjustment
d. Installation
INITIAL SETUP:
Test Equipment
References
Jumper wire
NONE
Equipment
Special Tools
Condition Condition Description
Para
NONE
NONE
Material/Parts
Special Environmental Conditions
NONE
NONE
Personnel Required
General Safety Instructions
1
NONE
LOCATION
ITEM
ACTION
REMARKS
TESTING
1. Engine
Start the engine and
operate at idle speed.
2. Time
a. Screws
Remove.
delay
(1),
washers
(2),
and
lock-
washers
(3)
b. Cover
Remove.
(4)
c. Jumper
Install across terminals
1 and 5.
3-1186


 