Custom Search
 
  
 
TM 55-1905-219-14-5
3-67. AIR INTAKE - MAINTENANCE INSTRUCTIONS.
The air intake shut-down housing, mounted on the side of the blower, serves as a mounting for the air cleaner. The air shut-
down housing contains an air shut-down valve that shuts off the air supply and stops the engine whenever abnormal operating
conditions require an emergency shut-down.
This task covers:
a. Inspection
c. Removal
e. Repair
b. Service
d. Disassembly
f. Installation
INITIAL SETUP:
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition Condition Description
Para
Torque wrench 0-50 ft. lb.
Air Cleaner Removal
Disassembly, Emergency
Shut-down Linkage
Disassembly, Shut-down
Material/Parts
Special Environmental Conditions
Repair Kit P/N 5193113
NONE
Oil MIL-L-2104 Type
OE/HDO-10
Personnel Required
General Safety Instructions
1
Observe all WARNINGS
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Air in-
a. Shut-
Inspect for binding.
Lubricate if
take
down
Disconnect latch from
binding, or re-
valve
ball joint and link.
place if re-
shaft
Move latch manually.
quired.