3-67. AIR INTAKE - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
7. Emer-
Cable and
Install.
Refer to para-
gency
linkage
shut-
down
8. Shut-
Linkage
Install.
Refer to para-
down
and brac-
sole-
ket
noid
9. Air
a. Cap-
Tighten.
Torque cap
in-
screw
screws evenly
take
(2)
to 16-20 lb.
and
ft. (21.8 to
those
27.3 Nm).
from
graph
b. Air
Install.
clean-
er
mount-
ing
tube
(1)
c.
Air
Check by starting and run-
in-
ning the generator engine
take
at idle speed and no load.
hous-
Trip the air shutdown. If
ing
the engine does not stop,
(4)
check for air leakage be-
tween the shutdown valve
(13) and the striker plate
(5). Re-position valve as
necessary.
d. Air
Install.
See paragraph
clean-