TM 55-1905-219-14-5
3-75. FRESH WATER PUMP - MAINTENANCE INSTRUCTIONS (Cont)
LOCATION
ITEM
ACTION
REMARKS
REPLACEMENT (Cont)
d. Fresh
1. Remove bolts (12) and
Use J 4242,
water
seal washers (13).
wrench, to
pump
loosen bolts.
2. Remove fresh water
pump (14) from blower.
3. Remove gasket (15).
Discard.
INSTALLATION
4. Fresh
a. Outlet
1. Place the outlet
water
flange
flange (10) on fresh
pump
water pump outlet
(11).
2. Slip outlet packing
Use repair kit,
(9) over fresh water
P/N 5193605.
pump outlet (11).
b. Fresh
1. Install gasket (15).
Use repair kit,
water
P/N 5193605.
pump
2. Place fresh water pump
Align and mesh
(14) against the
lugs on the
blower end plate.
drive coupling
with the lugs
on the inter-
mediate shaft
coupling.
3. Install seal washers
Tighten, secure
(13) and bolts (12).
to the blower.
3-1338
|
|