Custom Search
 
  
 
TM 55-1905-219-14-5
3-92.2. FLYWHEEL HOUSING - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
b. Position the dial in-
dicators straight and
square with the fly-
wheel housing bell
face and inside bore
of the bell. Make
sure each indicator
has adequate travel
in each direction.
NOTE
If the flywheel extends beyond the housing bell the bore and face must be checked
separately. Use the special adaptor in the tool set to check the housing bore.
c. Pry the crankshaft to-
ward one end play is
in one direction only.
d. Adjust each dial indi-
cator to read zero at
the twelve o'clock po-
sition. Then rotate
the crankshaft one
full revolution, tak-
ing readings at 450
intervals (8 readings
each for the bore and
the bolting flange
(face). Stop and re-
move the wrench or
cranking bar before
recording each reading
to ensure accuracy.
The maximum total
indicator reading must
not exceed .013" for
either the bore or the
face.
3-1619


 